Blancco LUN Eraser¶
Warning
This Plugin Provider implements non-recoverable disk wipe/erasure capabilities.
Running the workflows/workorders defined in this Plugin will completely and
irrevocably destroy all data as defined by the ble/wipe-disks
Param. There
is absolutely no way of recovering data from drives wiped with this tooling.
This plugin implements the commercially licensed industrial grade Disk and LUN wiping tool from Blancco Technology Group. The tool requires additional licensing direct from Blancco. The integrated product is Blancco LUN Eraser (BLE).
Note
RackN licenses do not entitle use of the Blancco LUN Eraser product. You must obtain use licenses directly from Blancco Technologies Group.
The product originates loosely from the open source Darik's Boot and Nuke (DBAN) disk wiping solution.
A short video on setting up a DRP Endpoint specifically to use the Blancco LUN Eraser, and then wiping systems with this integration can be found on Youtube.
Overview of Usage¶
This plugin requires external third party licenses to be purchased from Blancco to operate correctly. Product information and purchasing details can be found on Blancco's website at:
By default this plugin utilizes the Blancco Cloud services to validate and consume licenses, and upload completed Reports. The operator must have a valid Blancco Cloud account username and password with license entitlements. The Blancco Management Console can be found at:
It is possible to install a local (eg for "airgap" requirements) Blancco License and Console management service internally. Contact Blancco for further details.
Basic Usage¶
By default this content will not wipe any disks without a number of Params being set correctly on a target Machine. An example Profile can be found under Profiles, which provides a sample of Params that should be set. The example profile is named:
EXAMPLE-blancco-lun-eraser
Specifically, the following required Params must be set with values:
ble/username
- The Blancco Cloud or local Console server user accountble/password
- The Blancco Cloud or local Console server user passwordble/disks
- an array of disk targets to wipe, each disk consumes 1 (one) Blancco license entitlementble/wipe-disks
- set totrue
to enable disk wiping
Optional configuration Params can be set; if no value is specified, the default value will be used:
ble/noop-test-mode
- test the automation without running the wipe processes, for usage validation and disks selection verificationble/custom-report-fields
- adds custom fields to the completed wipe report, can use DRP based Golang template expansion in these, see the example Profileble/license-server
- defaults tohttps://cloud.blancco.com:443
ble/wipe-report-profile-tag
- if specified, collect DRP based combined report information in to a single Profile (see Profile Documentation for more details)ble/wipe-level
- defaults to16: NIST 800-88 Clear
ble/wipe-report-profile-tag
- no default - if set, enables aggregate Machine wipe reports written to a single Profileble/wipe-speedlimit
- defines a maximum I/O throughput in MB for wiping processes, see the BLE PDF documentation infiles/plugin_providers/blancco-lun-eraser
for more detailsble/wipe-buffersize
- I/O buffer size to use for wipping, can dramatically increase/decrease overall wipe process time, see the BLE PDF documentation infiles/plugin_providers/blancco-lun-eraser
for more detailsble/disks-target-param
- an alternate Param to use for the list of disks to wipe (for exampleinventory/Disks
)ble/disks-suppression-list
- a String List of disks to NOT wipe even if they have been explicitly specified to be wipedble/url-BlanccoLUNEraser-tool
- altnernate download location for the BLE binaryble/url-license-dat
- altnernate download location for thelicense.dat
ble/url-shasums
- altnernate download location for theble-sha256sums.txt
file, empty value turns off SHA hash checking
The Blancco LUN Eraser tooling supports several standards for different wipe
level requirements. See the ble/wipe-level
Param documentation for specific
standards supported wipe levels and setting values.
Note that the list of Optional/configuration params will grow and expand over time. Please see the individual Params defined in this Content for complete configuration capabilities and details.
Disk Selection, Suppression, and ReadOnly Handling¶
Normally the ble/disks
Param is the input definition for which target devices
should be wiped. The operator may override this to use any other Param that is
a List of Strings as an alternate input list. For example, by setting:
ble/disks-target-param: inventory/Disks
The system will use the disk devices identified in that alternate Param. In this example, this allows the standard Inventory collection processes in DRP to define the disk wipe target selection based on Inventory found devices.
In addition to the input Param definition of what disk devices to wipe, the operator can additionally choose to specify a Suppression (or "blacklist") of devices to NOT wipe. The primary intention of the suppression list to prevent erasure processes on non-writable disks (eg cdroms). However, the list can be used to ensure preservation of a specific devices from being wipe if desired.
By default the disk wipe suppression list contains /dev/sdr0
, /dev/cdrom
,
and /dev/dvd
.
In addition, any block device that are marked Read Only by the Linux Kernel
will automatically be removed from the target wipe list. Note that not all
actual Read Only devices are marked by the kernal as such. The system uses the
lsblk
device information output (which reads the kernel structures) to determine
which disks are Read Only.
Finally; the Task will remove any defined devices that do not have a block
device entry in /dev
correlating to the requested device.
Testing Without Wiping/Consuming Blancco Licenses¶
It is generally highly encouraged to test this automation prior to running any actual wipe/erasure operations on live disks. Each disk erasure or wipe process requires license entitlement and consumption from the Blancco Cloud management console or on-premises airgap Blancco Management Console.
To support test validations without actually wiping disks or consuming licenses, set the following Param:
ble/noop-test-mode: true
Info
The ble/wipe-disks
Param is a safety control setting. If set to
false
(the default value), then the erasure Tasks will completely
exit without running any subsequent code. This will NOT test the
tasks appropriately.
Most of all of the automation tooling will run, with the following exceptions:
- The
BlanccoLUNEraser
binary tool will not be executed - No reports will be generated and the report aggregation Profile writing will not be tested
Defining What to Erase¶
The BlanccoLUNEraser tool operates on LUNs (Logical Unit Numbers). LUNs may represent a group of drives configured as a single volume, a partition on a drive, or the entire drive itself.
The operator must provide an explicit list of LUNs that should be destroyed and wiped by setting the string list type Param to the names of the LUNs as will be found by the Sledgehammer operating system.
Typically, an operator can determine the LUN names by use of the lsblk
command while in the Sledgehammer environment (this may also be run on other
Linux variants, however device names are not guaranteed to match). Network
based LUNs can potentially be mounted in Sledgehammer to be presented for
wiping operations. These operations may be run via the Flexiflow task injection
pattern of the universal-discover
workflow.
At this time (as of v4.13.0) the system will not automatically wipe all drives on a system. It is possible that a new Task could be constructed to automatically determine a systems attached drives and build up the Param to support full system automatic wipe operations.
See the ble/wipe-disks
Params Documentation field for additional details.
License Availability Check¶
A limited attempt to determine if the defined Blancco Management Console (BMC)
(as defined by ble/license-server
) has valid licenses for consumption. If
no licenses are available, the process will exit with an error. This is
also true when ble/noop-test-mode
is enabled.
The license availability check does not (as of v4.13) attempt to validate licenses based on License Expire Date.
The tooling uses a fairly basic curl
call to the BMC to determine license
availability. It is possible this check may fail in a way that obscures
the failure reason. Typically this can be re-run with rs-debug-enable
set to true
, and reviewing the debug job log output for more clues.
Workflows¶
The Blancco LUN Eraser (BLE) tasks must be run in Sledgehammer. The following Workflow enforces that the machine is in Sledgehammer, then runs the Blancco LUN Eraser tooling Tasks:
blancco-lun-eraser
Workorders and Blueprints¶
The Blancco LUN Eraser (BLE) tasks must be run in Sledgehammer. The following Blueprint enforces that the machine is in Sledgehammer, then runs the Blancco LUN Eraser tooling Tasks:
blancco-lun-eraser
'universal-decommission' Integration¶
The Universal Decommission process (both an Infrastructure Pipeline and a
Workflow) can be flexibily extended to replace the standard drive erase
processes with the Blancco LUN Eraser tool. To do so, set the Flexiflow
Param that modifies the universal-decommission
Workflow stage named
universal-decommission-during-flexiflow
to inject the BlanccoLUNEraser
Tasks.
Doing this will replace the current Task list that typically runs in the Stage by default. Other desired Tasks can be added along with this.
Example usage by setting the following Param:
universal-decommission-during-flexiflow: [ "blancco-lun-eraser" ]
See the example Profile named EXAMPLE-BlanccoLUNEraser-universal-decommission
for further details.
Reporting for Disk Wipes¶
When utilizing the Blancco Cloud Management Console, completed wipe reports may be uploaded to the Console for review and certification proof of disk wipe operations. From time-to-time, the reports may fail to upload. In the case of a report upload failure, Digital Rebar Platform (DRP) will not fail the Task. The Job Log for the task will record the failure as a "500" error in the log.
Additionally, DRP records wipe results in the Blancco native Reporting format (XML)
as Params on the Machine, and optionally, in a Profile with an aggregate report
grouped together by an operator specified tag
value. This allows multiple
Machines to execute wipe operations, and aggregate the wipe reports together
in a single Profile.
A completed Wipe Report will be added to each Machine object of each Machine that completes a successful wipe. The wipe report will be recorded in the Param:
ble/wipe-report
The Optional Profile based aggregate reports must be explicitly enabled, if desired. To enable the Profile based reports, you must set the following Param with a "tag" value to identify this group of wipe operations. The tag is an arbitrary string, but should not contain any special characters. An example value setting:
ble/wipe-report-profile-tag
: "20240317-green"
In the above example a Profile will be created and the "tag" appended, creating a report Profile named:
ble-wipe-report-20240317-green
This Profile will be added to each machine. Each machines specific wipe report
will be written as a separate Param in the Profile, with the Machines UUID value
as the Param name, prefixed with machine-
.
Note
Reports are in Blannco's native reporting file format, which is XML.
To remove the report, you must remove the Profile from the Machine(s), then remove the Profile.
Warning
Subsequent re-runs of the blancco-lun-eraser
Workflow, with the
same Profile tag will cause older wipe records for a given Machine
(if they exist), to be deleted prior to the new Wipe Report being recorded.
Virtual Machines¶
If you are using Virtual Machines and wiping disk volumes, note that any of the erase levels implemented by Blancco LUN Eraser will cause the disk to inflate to its fully specified size. This is an important consideration if you are backing your disk volumes as Sparse type disks. You must ensure that your backing storage for your Virtual Machine volumes is large enough for the disks to be fully inflated.
Customizing the BlanccoLUNEraser Tool Operation¶
The BlanccoLUNEraser
(BLE) tool requires a separate configuration file which defines
the operational capabilities and enablement of the tools features. In addition,
the DRP implementation allows the operator to override the command line flags
and arguments for calling the tool. See the below sections for further details.
Configuring the BlanccoLUNEraser 'config.txt'¶
The BlanccoLUNEraser
tool utilizes a file with the name of config.txt
which
carries the configuraiton for the tool. By default, DRP will render the config
file as part of the operation of the tool, utilizing the Template named
blancco-lun-eraser-config.txt.tmpl
. This configuration file utilizes several
of the Params to create a customized configuration for each operational run of
the BLE tool.
The operator can construct and specify an alternative configuration file to be utilized by the BLE tool. To do so, set the DRP configuration Param to the name of an alternate Template with the desired customizations. An example is as follows:
ble/config-template: my-blanccoluneraser-config.txt.tmpl
This file is not validated for correctness by DRP. Any customizations to it must be validated against the BLE documentation.
BlanccoLUNEraser Binary Runtime Arguments¶
The BlanccoLUNEraser tool operates with a congirutaion file (defined above), in conjunction with a set of shell arguments. From time to time, Blancco may choose to update or change the arguments that are used. Subsequently, this would necessitate the update of the Plugin contents to adjust the arguments appropriately.
To ensure rapid updating of how the tooling is executed, it is possible to
specify alternative command line arguments to the binary tool (BlanccoLUNEraser
).
Note that ONLY the argument flags can be specified; and the Binary command
name may not (and SHOULD NOT) be specified in the Param.
The Param is defined as ble/wipe-command-arguments
. See the Params
Documentation field for additional customization information.
BlanccoLUNEraser Tool Documentation¶
For convenience the BlanccoLUNEraser tool documentation PDF is embedded in the DRP Plugin Provider. It will be installed and is available for review on the DRP Endpoint in the HTTP file server space. It can be found at:
- http://
:8091/files/plugin_providers/blancco-lun-eraser/ - or https://
:8090/files/plugin_providers/blancco-lun-eraser/
Note that RackN does not guarantee that the documentation in the PDF exactly matches the binary operation or usage.
Binary File Download Integrity Validation¶
If the Param ble/url-shasums
contains a file with sha256sums for the downloaded
assets (namely BlanccoLUNEraser
and license.dat
), then the files will be
validated after download.
If the Param is empty, the SHA hash checking will be skipped.