Multi-API OOB/BMC Control¶
The ipmi plugin adds the ability to do multi-vendor out-of band management (e.g. IPMI, Redfish, iDRAC, ILO, etc) actions on machines. Additionally, the plugin provides a stage, tasks, and parameters to facilitate the configuration of the BMC as part of a workflow. The plugin can also create machines from their BMC presence if the feature is enabled.
Training Video: https://www.youtube-nocookie.com/embed/Zs6KvwBvZYQ
!!! note To use this plugin, ipmitool
needs to be installed on the DRP endpoint. The plugin will fail to
load/configure if missing.
The following actions have become a loose API across all IPMI plugins.
-
Machine Actions:
poweron
poweroff
powercycle
nextbootpxe
nextbootdisk
identify
- not implemented by allpowerstatus
- not implemented by all
-
Plugin Actions:
range-scan
Each of these will be described more below. The actions trigger through the normal API conventions for machine actions.
API access is through the /api/v3/machines/UUID/actions/ACTION
POST endpoint. The drpcli actions
call drpcli machines runaction UUID ACTION
. Or UX as them on a dropdown in the Bulk Action section. See the other
sections of documentation for action information.
The configuration / discovery stage, ipmi-configure
, can be added to a workflow to at a minimum discover the machine's
BMC address, but additionally configure the BMC's networking and a single access user. There are parameters to describe
this behavior.
Each of the methods will be described below.
Configuration / Discovery¶
The ipmi-configure
stage when applied through a workflow can configure the BMC's network and configure a user for
out-of-band management operations. These configuration operations can be toggled on or off depending upon your
environment's needs. The user will be configured first and then the network configured.
The ipmi-configure
stage will take no actions by default. The stage has three task elements. The first is a task that
will make sure that the ipmitool is available and install it if missing. This is included in sledgehammer by default and
no action is required. The second task element is a quirks JSON file. This defines unique variations required to address
the variances in BMCs by hardware type. In general, this file does not need to be altered by the user. If a BMC
misbehaves, notify RackN with the problems. The third task element is the action configuration script itself. This does
the actual work and processes the quirks file as needed.
The ipmi-configure
stage can be told to fail if no BMC is detected. This is help if a BMC is broken or non-operative.
The ipmi/configure/no-bmc-fatal
boolean set to true
will cause failure in this case.
Regardless of what configuration parts the stage is allowed to do, the stage will always record the current IPMI network
address associated with the BMC and store that in the ipmi/address
parameter for the operational actions.
User Configuration¶
The ipmi-configure
stage will by default take no configuration actions. To enable user configuration,
the ipmi/configure/user
boolean will need to be set to true
. This can be done globally, in a profile attached to a
machine, or directly on the machine's parameters.
First, the ipmi-configure
task will check to see if the requested username, ipmi/configure/username
, is already
defined. If this is present, the userid is recorded. If the userid is not found, the ipmi-configure
task will check
the ipmi/configure/userid
parameter to see if a specific BMC numeric userid should be used for this control user. If
the userid is still not specified, a free userid will be found to user. If no userids are found, the first user id will
be overwritten.
Additional checks are performed to see if the first id (2) is editable. This is not the case on some BMCs.
Once a userid is selected or discovered, the username, password, privileges, and remote access are enabled for that
user. Once all those are success at the end of the task, the username and password are recorded in the ipmi/username
and ipmi/password
fields respectively.
Network Configuration¶
The ipmi-configure
stage will by default take no configuration actions. To enable network configuration,
the ipmi/configure/network
boolean will need to be set to true
. This can be done globally, in a profile attached to
a machine, or directly on the machine's parameters.
Once set to enabled, the first thing will be for Dell-based BMCs to have whether they are shared or dedicated set.
The task will then check to see if specific address is requested by seeing if the ipmi/configure/address
field is set.
If so and the ipmi/configure/reserve-ip
is set to true
, the task will create a Reservation for that IP address with
the BMC's MAC address in the DRP DHCP server. The task will fail if requested to reserve an address with no address
specified and set to static mode. This means that DRP is an IPAM and that is not currently supported.
With the reservation in place if requested, the stage will run use the ipmi/configure/ip-mode
to set which mode the
BMC should operate in. The options are dhcp or static. dhcp mode will enable the BMC to get an address through
DHCP. This address will get recorded into the ipmi/address
parameter.
If the mode is static, the ipmi/configure/address
, ipmi/configure/netmask
, and ipmi/configure/gateway
parameters
are used to set the BMC's network information.
Upon completion of everything, the current IP address will be recorded in the ipmi/address
parameters and a DRP DHCP
reservation will be created if the address was not specified in the ipmi/configure/address
parameter and DHCP mode was
set.
The overall flow of network configuration is to allow for static configuration (static mode), DHCP with an existing
reservation in the DHCP server (reserve-ip set to false
and dhcp mode), DHCP with a known address that becomes a
static DHCP address (reserve-ip set to true
, address specified in ipmi/configure/address
, and dhcp mode), and DHCP
without a known address that becomes statically bound in the DHCP server (reserve-ip set to true, address NOT specified
in ipmi/configure/address
, and dhcp mode).
Machine Creation¶
The goal of the DRP feature is to create machines via their BMC presence. DRP determines the presence of machines through events generated by the server or a manual range scan. It then logs in using default or user-provided credentials to determine access and creates a machine object.
Enabling Machine Discovery and Creation¶
In order to enable machine discovery and creation, the ipmi/discover/enabled
parameter must be set to true.
Machine Discovery from Lease Objects¶
Autodiscovery today is done from lease
events that are generated by the DRP server when a new DHCP lease is generated.
Setup¶
In order to enable auto-discovery of OOBM controllers, the ipmi/discover/enabled
and the ipmi/discover/from-lease
params should be set to true
.
In addition to this you will need to provide IPMI credentials which can be used to login to these controllers. This can be done in two ways:
- Using the
ipmi/discover/oobm-default-credentials
param which is a list of default credentials which will be used for all controllers - Using the
ipmi/discover/oobm-user-provided-credentials
which are credentials specific to a machine. The list uses an identifier per machine to determine what machine to try the credentials with. This identifier can be an IP address or the MAC address of the machine.
Optionally, you can also define the following params for further configuration:
-
ipmi/discover/parallel: The number of events that can be processed in parallel. Defaults to
200
. -
ipmi/discover/buffer-size: The number of events that are held in the queue at a given time. Defaults to
20000
. If the number of events exceeds the queue size, they will be lost. -
ipmi/discover/workflow: The workflow that needs to be set on the machine once it has been created. It defaults to
universal-discover
.
Process¶
The machine discovery and creation process consists of the following steps:
- Ensure that a machine with the same IP address or MAC address does not already exist. If a machine is found, the process stops.
- Ensure that the
Redfish
API is up and running and that we are able to login using the machine specific or the default credentials. We are unable to proceed without a successful login/connection. - Retrieve necessary information from the controller using
redfish
APIs. - Create a machine object with the retrieved information, IPMI information and the specified/default workflow.
Note
If any errors occur during this process, an error message is logged, and the process stops.
Range Scan¶
The setup is identical to the auto-discovery set up except the ipmi/discover/from-lease
param does not need to be set.
Process¶
- Ensure the IP addresses are in the right format
- Check that the start IP is lesser than the end IP
- Iterate over the list of IPs and for each IP follow the same process as auto discovery process
To perform a manual range scan, use drpcli
to run an action against the ipmi plugin.
drpcli plugins runaction ipmi scan-range ipmi/discover/scan-start-address "1.1.1.1" ipmi/discover/scan-end-address "2.2.2.2"
Note
Finalization¶
Once configuration is finished, some BMCs need to be reset to take effect. This can take up to a minute in some cases.
Actions¶
Actions are enabled on the machines by have three parameters set. Actions will not be visible upon the machines if not
present. The following parameters need to be set somehow. If the ipmi-configure
stage is NOT used, the IPMI actions
can still function if the following three parameters are applied to the machine in some manner.
Parameters:
* `ipmi/address` - The IP address to access the BMC
* `ipmi/username` - The username to initiate BMC actions
* `ipmi/password` - The password to initiate BMC actions
Optionally, the network Port to connect to can be defined if the specific ipmi/mode
driver type has been configured to
use non-standard Port numbers for the given protocol. For example, if the IPMI protocol has been relocated from default
UDP port 623 to 1623, use the appropriate optional Param setting below. The options are as follows:
- (optional)
ipmi/port-ipmitool
- sets the network Port for the IPMI protocol - (optional)
ipmi/port-racadm
- sets the network Port for the iDRAC RACADM commands - (optional)
ipmi/port-redfish
- sets the network Port for the Redfish API service
The configuration parts of the ipmi-configure
stage will set all three if enabled. Without configuration enabled,
the ipmi/address
field will be populated regardless if the ipmi-configure
stage is applied. This enables discovery
of BMC addresses for existing or already configured systems.
The ipmi/address
parameter should be unique to the machine and specified directly in the machine's parameters.
The ipmi/username
and ipmi/password
fields may be specified directly in the machine's parameters, in a profile
attached to the machine, or global profile depending upon the scope of the username and password in the environment.
Using those three parameters, the actions will use ipmitool do the following actions. The administrator will need to make sure that the DRP Endpoint can access the BMC addresses.
All actions will return a 200 HTTP return code and a string of the ipmitool output. Upon failure, a 409 HTTP return code is returned and the error output of the ipmitool command.
powerstatus¶
This will issue chassis power status and return the results as a string.
poweron¶
This will issue chassis power on and return the results as a string.
poweroff¶
This will issue chassis power off and return the results as a string.
powercycle¶
This will issue chassis power cycle and return the results as a string.
nextbootpxe¶
This will issue chassis bootdev pxe and return the results as a string. This will be a single next boot action to boot from the network. On most systems, this is not persistent.
nextbootdisk¶
This will issue chassis bootdev disk and return the results as a string. This will be a single next boot action to boot from the disk. On most systems, this is not persistent.
identify¶
This will issue chassis identify number and return the results as a string. The number is specified by
the ipmi/identify-duration
parameter and defaults to 60 (seconds).
range-scan¶
The action allows you to scan a range of IPs to detect BMC presence by setting the ipmi/discover/scan-start-address
and ipmi/discover/scan-end-address
params. If a BMC is detected, DRP attempts to log in using default or user-provided
credentials. If successful, a machine object will be created. Also
see [machine discovery]{#rs_ipmi_scanning}
Potential Errors¶
In configuring various ipmi/mode
types, you may receive errors when Actions are performed. Some of those errors may
include the following, along with potential reasons for the error condition.
* `(404) plugin: ipmi out: Error: Unable to establish IPMI v2 / RMCP+ session`
Typically this error may be encountered, the IPMI protocol mode has not been enabled on the Baseboard Management Controller (BMC; Dell iDRAC, HPE iLO, etc.).