RAID¶
The raid plugin provides two pieces to the system.
- A content pack with stages, tasks, and parameters
- A go-binary that can run in sledgehammer to take actions
These two pieces together work to configure and manage the hardware raid subsystem of a physical machine.
Operational Information¶
The raid plugin provides a set of operational and example stages for configuring the hardware raid subsystem.
Provided Stages:
raid-inventory
- Provides an inventory of the raid subsystemraid-enable-encryption
- Configures controller level encryptionraid-configure
- Configures the volumes on the raid systemraid-reset
- Resets the skip parameters to allow for reconfigurationraid-baseline
- Snapshots the current configuration into a usableraid-target-configuration
parameterraid-example
- Historical stage that got split intoraid-configure
andraid-inventory
The stages make sure that the appropriate raid tools are installed.
The system uses two toggle parameters to make sure that once configured the
RAID configuration is not altered. raid-skip-config
and raid-skip-encryption
parameters to ensure that the RAID subsystem does NOT get altered once configured.
To enable reconfiguration, clear these parameters from the machine's object or
use the raid-reset
stage or task in your workflow.
Digital Rebar RAID Configuration Tool¶
The Digital Rebar RAID configuration tool (also known as drp-raid) is designed to be an automated wrapper around lower-level RAID configuration tools. It is designed to work with the RAID workload in the Sledgehammer environment.
Usage¶
By default, drp-raid
will attempt to operate on all controllers
present in the system. If a specific controller is desired,
the controller should be specified in the configuration structures.
drp-raid can perform a few common tasks:
Report Current Configuration¶
drp-raid
with no arguments reports on the current state of all the
RAID controllers it knows about, including the state of all physical
drives and volumes. This report is output in the form of a JSON array
of controllers.
Clear All Configuration¶
drp-raid-clear
will clear all configuration on all RAID controllers
attached to the system, including any foreign configuration.
The -force
flag can be used to set the disks to a GOOD
state once the configuration has been wiped.
Show Current Volume Specifications¶
drp-raid-volspecs
shows the current list of volumes on all RAID
controllers in the system in a form that can be fed into drp-raid
-configure
to recreate the volumes as they are.
Additionally, the -generic
flag can be given to the command to
create volspecs that are less disk specific in format. The normal
mode generates a disk entry for each disk in the volume. The
generic mode will generate counts instead of specific drives.
Compile Volume Specifications Into Final Format¶
drp-raid-compile
takes a list of volume specifications on stdin,
compiles them to a format suitable for the current system (including
resolving what drives to use and what the approximate final size of
each given volume will be), and outputs that list on stdout. It
assumes that the RAID controllers are unconfigured, and it will change
the current RAID configuration.
Configure Volumes on Raid Controllers¶
drp-raid-configure
takes a list of volume specifications on stdin,
compiles them, and then attempts to create any needed volumes on the
RAID controllers. Existing volumes will not be modified or deleted.
The -force
flag can be used to set the disks to a GOOD
state prior to adding the drive to its volume.
Add Volumes to Raid Controllers¶
drp-raid-append
attemps to add the list of volume specifications
from stdin to the preexisting volumes. Unlike configure, you do not
need to pass in volume specifications for existing volumes.
Encrypt Raid Controllers¶
drp-raid-encrypt
attemps to configure the global encryption settings
for the specified raid controller. This requires additional parameters:
- -key - the base key for the system.
- -password - the base password for the system.
The content tasks use parameters to fill these in automatically.
Supported RAID Controllers¶
drp-raid supports all RAID controllers supported by current MegaCLI and StorCLI tooling for Avago-based RAID controllers, along with all HP SmartArray controllers that are manageable by ssacli. Additional controllers supported by the PercCLI and MVCli tool chains. Support for other tools and RAID controller types can be added as part of a consulting or support engagement, depending in your license terms.
Volume Specifications¶
Volume specifications (volspecs for short) are what drp-raid uses to configure RAID volumes, no matter what RAID toolset or controller type you are using. A list of volume specifications looks like this json:
[
{
"RaidLevel": "string",
"Size": "string",
"StripeSize": "string",
"Name": "string",
"VolumeID": "string",
"Bootable": false,
"Type": "string",
"Protocol": "string",
"Controller": 0,
"DiskCount": "string",
"Encrypt": boolean,
"AllowMixedSizes": boolean,
"Disks": [
{
"Size": 0,
"Slot": 0,
"Enclosure": "string",
"Type": "string",
"Protocol": "string",
"Volume": "string"
}
]
}
]
Each field in a volume specification is defined as follows:
-
Controller: an integer that specifies which discovered controller the RAID volume should be created on. drp-raid orders controllers based on PCI address. This value defaults to 0, indicating that the volume will be built on the first discovered controller.
-
RaidLevel: A string value that specifies what level of RAID to build. RaidLevel must be present in all volspecs, and it has no default. Valid RaidLevels are:
- "jbod": All disks in this volspec should be turned into JBOD volumes. If a given RAID controller does not support jbod mode, a single-disk RAID0 will be created for each disk instead.
- "concat": The disks should be concatenated.
- "raid0": Make a RAID0 with the chosen disks.
- "raid1": Make a RAID1 with the chosen disks.
- "raid5": Make a RAID5 with the chosen disks.
- "raid6": Make a RAID6 with the chosen disks.
- "raid00": Make a RAID00 with the chosen disks.
- "raid10": Make a RAID10 with the chosen disks.
- "raid1e": Make a RAID1e with the chosen disks.
- "raid50": make a RAID50 with the chosen disks.
- "raid60": make a RAID60 with the chosen disks.
- "raidS": Works like jbod, but makes raid0 volumes.
Not all RAID controllers will support the above RAID levels, and with the exception of jbod if a RAID level is not supported then volume creation will fail.
-
Disks: A list of physical disk specifiers that indicate which physical disks should be used to create the volume. When creating a volume by specifying individual disks, you are responsible for making sure that the choice of disks is sane for the desired controller. If Disks is specified, then DiskCount is ignored and drp-raid will not perform more than minimal sanity checking on the disks provided. Each entry in the Disks list must contain the following fields:
- "Enclosure": a string that identifies which enclosure the disk is in.
- "Slot": a number that identifies which slot in the Enclosure the desired physical disk is in.
-
DiskCount: The number of disks that should be used to build the desired volume. DiskCount can be one of the following:
- "min", which indicates that the smallest number of disks that can be used for the requested RaidLevel whould be used.
- "max", which indicates that the largest number of disks with the same Type and Protocol should be used.
- A positive integer.
If DiskCount is unspecified and Disks is also unspecified, DiskCount will default to "min".
-
Size: A string value that indicates what the desired total useable size of the RAID array should be. When you let drp-raid decide what physical disks to pick for volume creation, it will pick the smallest disks that can be used to satisfy the volume creation request. Size can be one of the following values:
- "min", which will pick the smallest disks that meet the rest of the constraints in the volspec.
- "max", which will pick the largest disks that meet the rest of the constraints in the volspec.
- A string containing a human-readable size (100 MB, 1 TB, 5 PB).
If Size is unspecified or left blank, it will default to "max".
-
Type: A comma-separated list of disk types that should be tried in order when creating a volume. Currently, individual items can be "disk" for rotational disks, and "ssd" for solid-state disks. If unspecified, "disk,ssd" will be used. All physical disks in a created volume will be of the same type, and it is perrmitted to have a list with one entry.
-
Protocol: A comma-separated list of low-level protocols that should be tried in order when creating a volume. Currently, individual items can be "sata" for disks that communicate using the SATA protocol, and "sas" for disks that communicate using the SAS protocol. All physical disks in a created volume will communicate using the same protocol, and it is perrmitted to have a list with one entry.
-
StripeSize: A string containing the human-readable size of each individual stripe in the RAID array. It is generally a power of two less than or equal to 1 MB. If unspecified, it defaults to "64 KB".
-
Name: The desired name of the volume, if the RAID controller supports naming volumes. Naming a volume is currently unsupported.
-
VolumeID: The controller-specific ID of the created volume.
-
Bootable: A boolean value indicating whether this volume should be the default one the RAID controller will use when booting the system. Defaults to false, and Bootable support is currently not implemented.
-
Encrypt: Whether the volume should be transparently encrypted by the RAID controller. This requires controller-specific setup.
-
AllowMixedSizes: Whether we will create a volume that spans physical disks of wildly mixed sizes. By default, we will fail if we pick disks underlying a volume that vary in size by more than 10%.
Example Transcript¶
[root@df8-bc-12-41-c4-72 ~]# ./drp-raid -clear
[root@df8-bc-12-41-c4-72 ~]# ./drp-raid
[
{
"ID": "0",
"Driver": "storcli7",
"PCI": {
"Bus": 10,
"Device": 0,
"Function": 0
},
"JBODCapable": false,
"RaidCapable": true,
"RaidLevels": [
"raid0",
"raid1",
"raid5",
"raid6",
"raid00",
"raid10",
"raid50",
"raid60"
],
"Volumes": [],
"Disks": [
{
"ControllerID": "0",
"ControllerDriver": "storcli7",
"VolumeID": "",
"Enclosure": "252",
"Size": 499558383616,
"UsedSize": 0,
"SectorCount": 975699968,
"PhysicalSectorSize": 512,
"LogicalSectorSize": 512,
"Slot": 0,
"Protocol": "sata",
"MediaType": "disk",
"Status": "Unconfigured(good), Spun Up",
"Info": {
"Coerced Size": "465.25 GB [0x3a280000 Sectors]",
"Connected Port Number": "2(path0)",
"Device Firmware Level": "1S04",
"Device Id": "1",
"Device Speed": "3.0Gb/s",
"Drive": "Not Certified",
"Drive has flagged a S.M.A.R.T alert": "No",
"Drive is formatted for PI information": "No",
"Drive's NCQ setting": "N/A",
"Enclosure Device ID": "252",
"Enclosure position": "0",
"FDE Capable": "Not Capable",
"FDE Enable": "Disable",
"Firmware state": "Unconfigured(good), Spun Up",
"Foreign State": "None",
"Inquiry Data": "WD-WMAYP8041031WDC WD5003ABYX-18WERA0 01.01S04",
"Last Predictive Failure Event Seq Number": "0",
"Link Speed": "3.0Gb/s",
"Locked": "Unlocked",
"Logical Sector Size": "512",
"Media Error Count": "0",
"Media Type": "Hard Disk Device",
"Needs EKM Attention": "No",
"Non Coerced Size": "465.261 GB [0x3a286030 Sectors]",
"Other Error Count": "0",
"PD Type": "SATA",
"PI": "No PI",
"PI Eligibility": "No",
"Physical Sector Size": "512",
"Port status": "Active",
"Port's Linkspeed": "3.0Gb/s",
"Predictive Failure Count": "0",
"Raw Size": "465.761 GB [0x3a386030 Sectors]",
"SAS Address(0)": "0x4433221103000000",
"Secured": "Unsecured",
"Sequence Number": "27",
"Shield Counter": "0",
"Slot Number": "0",
"Successful diagnostics completion on": "N/A",
"WWN": "50014ee0ae7b61c5"
}
},
{
"ControllerID": "0",
"ControllerDriver": "storcli7",
"VolumeID": "",
"Enclosure": "252",
"Size": 499558383616,
"UsedSize": 0,
"SectorCount": 975699968,
"PhysicalSectorSize": 512,
"LogicalSectorSize": 512,
"Slot": 1,
"Protocol": "sata",
"MediaType": "disk",
"Status": "Unconfigured(good), Spun Up",
"Info": {
"Coerced Size": "465.25 GB [0x3a280000 Sectors]",
"Connected Port Number": "1(path0)",
"Device Firmware Level": "1S04",
"Device Id": "2",
"Device Speed": "3.0Gb/s",
"Drive": "Not Certified",
"Drive has flagged a S.M.A.R.T alert": "No",
"Drive is formatted for PI information": "No",
"Drive's NCQ setting": "N/A",
"Enclosure Device ID": "252",
"Enclosure position": "0",
"FDE Capable": "Not Capable",
"FDE Enable": "Disable",
"Firmware state": "Unconfigured(good), Spun Up",
"Foreign State": "None",
"Inquiry Data": "WD-WMAYP7926193WDC WD5003ABYX-18WERA0 01.01S04",
"Last Predictive Failure Event Seq Number": "0",
"Link Speed": "3.0Gb/s",
"Locked": "Unlocked",
"Logical Sector Size": "512",
"Media Error Count": "0",
"Media Type": "Hard Disk Device",
"Needs EKM Attention": "No",
"Non Coerced Size": "465.261 GB [0x3a286030 Sectors]",
"Other Error Count": "0",
"PD Type": "SATA",
"PI": "No PI",
"PI Eligibility": "No",
"Physical Sector Size": "512",
"Port status": "Active",
"Port's Linkspeed": "3.0Gb/s",
"Predictive Failure Count": "0",
"Raw Size": "465.761 GB [0x3a386030 Sectors]",
"SAS Address(0)": "0x4433221102000000",
"Secured": "Unsecured",
"Sequence Number": "27",
"Shield Counter": "0",
"Slot Number": "1",
"Successful diagnostics completion on": "N/A",
"WWN": "50014ee05925c428"
}
},
{
"ControllerID": "0",
"ControllerDriver": "storcli7",
"VolumeID": "",
"Enclosure": "252",
"Size": 499558383616,
"UsedSize": 0,
"SectorCount": 975699968,
"PhysicalSectorSize": 512,
"LogicalSectorSize": 512,
"Slot": 2,
"Protocol": "sata",
"MediaType": "disk",
"Status": "Unconfigured(good), Spun Up",
"Info": {
"Coerced Size": "465.25 GB [0x3a280000 Sectors]",
"Connected Port Number": "3(path0)",
"Device Firmware Level": "1S04",
"Device Id": "3",
"Device Speed": "3.0Gb/s",
"Drive": "Not Certified",
"Drive has flagged a S.M.A.R.T alert": "No",
"Drive is formatted for PI information": "No",
"Drive's NCQ setting": "N/A",
"Enclosure Device ID": "252",
"Enclosure position": "0",
"FDE Capable": "Not Capable",
"FDE Enable": "Disable",
"Firmware state": "Unconfigured(good), Spun Up",
"Foreign State": "None",
"Inquiry Data": "WD-WMAYP8040536WDC WD5003ABYX-18WERA0 01.01S04",
"Last Predictive Failure Event Seq Number": "0",
"Link Speed": "3.0Gb/s",
"Locked": "Unlocked",
"Logical Sector Size": "512",
"Media Error Count": "0",
"Media Type": "Hard Disk Device",
"Needs EKM Attention": "No",
"Non Coerced Size": "465.261 GB [0x3a286030 Sectors]",
"Other Error Count": "0",
"PD Type": "SATA",
"PI": "No PI",
"PI Eligibility": "No",
"Physical Sector Size": "512",
"Port status": "Active",
"Port's Linkspeed": "3.0Gb/s",
"Predictive Failure Count": "0",
"Raw Size": "465.761 GB [0x3a386030 Sectors]",
"SAS Address(0)": "0x4433221101000000",
"Secured": "Unsecured",
"Sequence Number": "21",
"Shield Counter": "0",
"Slot Number": "2",
"Successful diagnostics completion on": "N/A",
"WWN": "50014ee0ae7b6632"
}
},
{
"ControllerID": "0",
"ControllerDriver": "storcli7",
"VolumeID": "",
"Enclosure": "252",
"Size": 499558383616,
"UsedSize": 0,
"SectorCount": 975699968,
"PhysicalSectorSize": 512,
"LogicalSectorSize": 512,
"Slot": 3,
"Protocol": "sata",
"MediaType": "disk",
"Status": "Unconfigured(good), Spun Up",
"Info": {
"Coerced Size": "465.25 GB [0x3a280000 Sectors]",
"Connected Port Number": "0(path0)",
"Device Firmware Level": "1S04",
"Device Id": "0",
"Device Speed": "3.0Gb/s",
"Drive": "Not Certified",
"Drive has flagged a S.M.A.R.T alert": "No",
"Drive is formatted for PI information": "No",
"Drive's NCQ setting": "N/A",
"Enclosure Device ID": "252",
"Enclosure position": "0",
"Exit Code": "0x00",
"FDE Capable": "Not Capable",
"FDE Enable": "Disable",
"Firmware state": "Unconfigured(good), Spun Up",
"Foreign State": "None",
"Inquiry Data": "WD-WMAYP8042658WDC WD5003ABYX-18WERA0 01.01S04",
"Last Predictive Failure Event Seq Number": "0",
"Link Speed": "3.0Gb/s",
"Locked": "Unlocked",
"Logical Sector Size": "512",
"Media Error Count": "0",
"Media Type": "Hard Disk Device",
"Needs EKM Attention": "No",
"Non Coerced Size": "465.261 GB [0x3a286030 Sectors]",
"Other Error Count": "0",
"PD Type": "SATA",
"PI": "No PI",
"PI Eligibility": "No",
"Physical Sector Size": "512",
"Port status": "Active",
"Port's Linkspeed": "3.0Gb/s",
"Predictive Failure Count": "0",
"Raw Size": "465.761 GB [0x3a386030 Sectors]",
"SAS Address(0)": "0x4433221100000000",
"Secured": "Unsecured",
"Sequence Number": "21",
"Shield Counter": "0",
"Slot Number": "3",
"Successful diagnostics completion on": "N/A",
"WWN": "50014ee003d097f2"
}
}
],
"Info": {
"Access Policy": "Yes",
"Alarm": "Present",
"Alarm Control": "Yes",
"Alarm Disable": "Yes",
"Allow Boot with Preserved Cache": "No",
"Allow Ctrl Encryption": "No",
"Allow HDD SAS/SATA Mix in VD": "Yes",
"Allow HDD/SSD Mix in VD": "Yes",
"Allow Mix in Enclosure": "Yes",
"Allow Mixed Redundancy on Array": "No",
"Allow SATA in Cluster": "No",
"Allow SSD SAS/SATA Mix in VD": "Yes",
"Allowed Device Type": "SAS/SATA Mix",
"Any Offline VD Cache Preserved": "No",
"Auto Detect BackPlane Enable": "SGPIO/i2c SEP",
"Auto Detect BackPlane Enabled": "SGPIO/i2c SEP",
"Auto Enhanced Import": "Yes",
"Auto Rebuild": "Enabled",
"BBU": "Absent",
"BGI Rate": "30%",
"BIOS Continue on Error": "Yes",
"BIOS Enumerate VDs": "Yes",
"BIOS Version": "3.30.02.2_4.16.08.00_0x06060A05",
"BOOT Version": "09.250.01.219",
"Background Rate": "30",
"Battery FRU": "N/A",
"Battery Warning": "Disabled",
"Block SSD Write Disk Cache Change": "No",
"Boot Block Version": "2.02.00.00-0000",
"Boot Volume Supported": "NO",
"BreakMirror RAID Support": "Yes",
"CC Rate": "Yes",
"Cache Flush Interval": "4s",
"Cache When BBU Bad": "Disabled",
"Cached IO": "No",
"Check Consistency Rate": "30%",
"ChipRevision": "B4",
"Cluster Active": "No",
"Cluster Disable": "Yes",
"Cluster Mode": "Disabled",
"Cluster Permitted": "No",
"Cluster Support": "No",
"Coercion Mode": "None",
"Controller Id": "0000",
"Critical Disks": "0",
"Current Size of CacheCade": "0 GB",
"Current Size of FW Cache": "346 MB",
"Current Time": "21:21:25 2/14, 2018",
"Dedicated Hot Spare": "Yes",
"Default LD PowerSave Policy": "Controller Defined",
"Default spin down time in minutes": "30",
"Degraded": "0",
"Delay Among Spinup Groups": "2s",
"Delay during POST": "0",
"Deny CC": "No",
"Deny Clear": "No",
"Deny Force Failed": "No",
"Deny Force Good/Bad": "No",
"Deny Locate": "No",
"Deny Missing Replace": "No",
"Deny SCSI Passthrough": "No",
"Deny SMP Passthrough": "No",
"Deny STP Passthrough": "No",
"Device Id": "0079",
"Device Interface": "PCIE",
"Direct PD Mapping": "No",
"Dirty LED Shows Drive Activity": "No",
"Disable Copyback": "No",
"Disable Ctrl-R": "Yes",
"Disable Join Mirror": "No",
"Disable Online Controller Reset": "No",
"Disable Online PFK Change": "No",
"Disable Puncturing": "No",
"Disable Spin Down of hot spares": "No",
"Disk Cache Policy": "Yes",
"Disks": "4",
"ECC Bucket Count": "0",
"Ecc Bucket Leak Rate": "1440 Minutes",
"Ecc Bucket Size": "15",
"Enable Copyback on SMART": "No",
"Enable Copyback to SSD on SMART Error": "Yes",
"Enable JBOD": "No",
"Enable LDBBM": "Yes",
"Enable Led Header": "Yes",
"Enable SSD Patrol Read": "No",
"Enable Shield State": "No",
"Enable Spin Down of UnConfigured Drives": "Yes",
"Enable Web BIOS": "Yes",
"EnableCrashDump": "No",
"EnableLDBBM": "Yes",
"Exit Code": "0x00",
"Expose Enclosure Devices": "Enabled",
"FW Package Build": "12.15.0-0239",
"FW Version": "2.130.403-4660",
"Failed Disks": "0",
"Flash": "Present",
"Flush Time": "4 seconds",
"Force Offline": "Yes",
"Force Online": "Yes",
"Force Rebuild": "Yes",
"Foreign Config Import": "Yes",
"Global Hot Spares": "Yes",
"Host Interface": "PCIE",
"Host Request Reordering": "Enabled",
"IO Policy": "Yes",
"Interrupt Throttle Active Count": "16",
"Interrupt Throttle Completion": "50us",
"LED Show Drive Activity": "Yes",
"Load Balance Mode": "Auto",
"Maintain PD Fail History": "Enabled",
"Max Arms Per VD": "32",
"Max Arrays": "128",
"Max Chained Enclosures": "16",
"Max Configurable CacheCade Size": "0 GB",
"Max Data Transfer Size": "8192 sectors",
"Max Drives to Spinup at One Time": "4",
"Max LD per array": "16",
"Max Number of VDs": "64",
"Max Parallel Commands": "1008",
"Max SGE Count": "80",
"Max Spans Per VD": "8",
"Max Strip Size": "1.0 MB",
"Max Strips PerIO": "42",
"Maximum number of direct attached drives to spin up in 1 min": "120",
"Memory": "Present",
"Memory Correctable Errors": "0",
"Memory Size": "512MB",
"Memory Uncorrectable Errors": "0",
"Mfg. Date": "03/13/12",
"Min Strip Size": "8 KB",
"NCQ": "No",
"NVDATA Version": "2.09.03-0058",
"NVRAM": "Present",
"Number of Backend Port": "8",
"Number of Frontend Port": "0",
"Offline": "0",
"On board Expander": "Absent",
"PFK TrailTime Remaining": "0 days 0 hours",
"PFK in NVRAM": "No",
"POST delay": "90 seconds",
"PR Correct Unconfigured Areas": "Yes",
"PR Rate": "30%",
"Patrol Read Rate": "Yes",
"Phy Polarity": "0",
"Phy PolaritySplit": "0",
"Physical Devices": "5",
"Physical Drive Coercion Mode": "Disabled",
"Point In Time Progress": "No",
"Power Saving option": "Don't Auto spin down Configured Drives",
"Power Savings": "No",
"PreBoot CLI Enabled": "Yes",
"Preboot CLI Version": "04.04-020:#%00009",
"Predictive Fail Poll Interval": "300sec",
"Product Name": "LSI MegaRAID SAS 9260-8i",
"RAID Level Supported": "RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span",
"Read Policy": "Yes",
"Rebuild Rate": "30%",
"Reconstruct Rate": "Yes",
"Reconstruction": "Yes",
"Reconstruction Rate": "30%",
"Restore Hot Spare on Insertion": "No",
"Restore HotSpare on Insertion": "Disabled",
"Revertible Hot Spares": "Yes",
"Revision No": "79B",
"Rework Date": "00/00/00",
"SAS Address": "500605b004872390",
"SAS Disable": "No",
"SMART Mode": "Mode 6",
"Security Key Assigned": "No",
"Security Key Failed": "No",
"Security Key Not Backedup": "No",
"Self Diagnostic": "Yes",
"Serial Debugger": "Present",
"Serial No": "SV21106771",
"Snapshot Enabled": "No",
"Spanning": "Yes",
"Spin Down Mode": "None",
"Spin Down time": "30",
"Strip Size": "256kB",
"SubDeviceId": "9261",
"SubVendorId": "1000",
"Support Boot Time PFK Change": "No",
"Support Breakmirror": "No",
"Support PFK": "Yes",
"Support PI": "No",
"Support Security": "No",
"Support Shield State": "No",
"Support Temperature": "Yes",
"Support the OCE without adding drives": "Yes",
"Supported Drives": "SAS, SATA",
"T10 Power State": "No",
"TPM": "Absent",
"TTY Log In Flash": "No",
"Temperature sensor for ROC": "Absent",
"Temperature sensor for controller": "Absent",
"Time taken to detect CME": "60s",
"Topology Type": "None",
"Treat Single span R1E as R10": "No",
"Un-Certified Hard Disk Drives": "Allow",
"Upgrade Key": "Absent",
"Use FDE Only": "No",
"Use disk activity for locate": "No",
"Vendor Id": "1000",
"Virtual Drives": "0",
"WebBIOS Version": "6.0-54-e_50-Rel",
"Write Policy": "Yes",
"ZCR Config": "Unknown",
"Zero Based Enclosure Enumeration": "No"
}
}
]
[root@df8-bc-12-41-c4-72 ~]# ./drp-raid -volspecs
[]
[root@df8-bc-12-41-c4-72 ~]# echo '[{"RaidLevel": "raid1","DiskCount": "min"},{"RaidLevel": "raid1","DiskCount": "min"}]' |./drp-raid -compile
[
{
"RaidLevel": "raid1",
"Size": "465.25 GB",
"StripeSize": "64 KB",
"Name": "",
"VolumeID": "",
"Bootable": false,
"Type": "disk",
"Protocol": "sata",
"Controller": 0,
"Disks": [
{
"Size": 499558383616,
"Slot": 0,
"Enclosure": "252",
"Type": "disk",
"Protocol": "sata",
"Volume": ""
},
{
"Size": 499558383616,
"Slot": 1,
"Enclosure": "252",
"Type": "disk",
"Protocol": "sata",
"Volume": ""
}
],
"DiskCount": ""
},
{
"RaidLevel": "raid1",
"Size": "465.25 GB",
"StripeSize": "64 KB",
"Name": "",
"VolumeID": "",
"Bootable": false,
"Type": "disk",
"Protocol": "sata",
"Controller": 0,
"Disks": [
{
"Size": 499558383616,
"Slot": 2,
"Enclosure": "252",
"Type": "disk",
"Protocol": "sata",
"Volume": ""
},
{
"Size": 499558383616,
"Slot": 3,
"Enclosure": "252",
"Type": "disk",
"Protocol": "sata",
"Volume": ""
}
],
"DiskCount": ""
}
]
[root@df8-bc-12-41-c4-72 ~]# echo '[{"RaidLevel": "raid1","DiskCount": "min"}]' |./drp-raid -configure
2018/02/14 21:22:28 Adapter 0: Created VD 0
Adapter 0: Configured the Adapter!!
Exit Code: 0x00
2018/02/14 21:22:28 Created raid1 on storcli7:0
[root@df8-bc-12-41-c4-72 ~]# echo '[{"RaidLevel": "raid1","DiskCount": "min"}]' |./drp-raid -configure
2018/02/14 21:22:43 All volumes already present, nothing to to
[root@df8-bc-12-41-c4-72 ~]# ./drp-raid -volspecs
[
{
"RaidLevel": "raid1",
"Size": "465.25 GB",
"StripeSize": "64 KB",
"Name": "",
"VolumeID": "0",
"Bootable": false,
"Type": "disk",
"Protocol": "sata",
"Controller": 0,
"Disks": [
{
"Size": 499558383616,
"Slot": 0,
"Enclosure": "252",
"Type": "disk",
"Protocol": "sata",
"Volume": "0"
},
{
"Size": 499558383616,
"Slot": 1,
"Enclosure": "252",
"Type": "disk",
"Protocol": "sata",
"Volume": "0"
}
],
"DiskCount": ""
}
]
[root@df8-bc-12-41-c4-72 ~]# echo '[{"RaidLevel": "raid1","DiskCount": "min"}]' |./drp-raid -append
2018/02/14 21:23:13 Adapter 0: Created VD 1
Adapter 0: Configured the Adapter!!
Exit Code: 0x00
2018/02/14 21:23:13 Created raid1 on storcli7:0
[root@df8-bc-12-41-c4-72 ~]# ./drp-raid -volspecs
[
{
"RaidLevel": "raid1",
"Size": "465.25 GB",
"StripeSize": "64 KB",
"Name": "",
"VolumeID": "0",
"Bootable": false,
"Type": "disk",
"Protocol": "sata",
"Controller": 0,
"Disks": [
{
"Size": 499558383616,
"Slot": 0,
"Enclosure": "252",
"Type": "disk",
"Protocol": "sata",
"Volume": "0"
},
{
"Size": 499558383616,
"Slot": 1,
"Enclosure": "252",
"Type": "disk",
"Protocol": "sata",
"Volume": "0"
}
],
"DiskCount": ""
},
{
"RaidLevel": "raid1",
"Size": "465.25 GB",
"StripeSize": "64 KB",
"Name": "",
"VolumeID": "1",
"Bootable": false,
"Type": "disk",
"Protocol": "sata",
"Controller": 0,
"Disks": [
{
"Size": 499558383616,
"Slot": 2,
"Enclosure": "252",
"Type": "disk",
"Protocol": "sata",
"Volume": "1"
},
{
"Size": 499558383616,
"Slot": 3,
"Enclosure": "252",
"Type": "disk",
"Protocol": "sata",
"Volume": "1"
}
],
"DiskCount": ""
}
]
[root@df8-bc-12-41-c4-72 ~]# echo '[{"RaidLevel": "raid1","DiskCount": "min"},{"RaidLevel": "raid1","DiskCount": "min"}]' |./drp-raid -configure
2018/02/14 21:23:58 All volumes already present, nothing to to
[root@df8-bc-12-41-c4-72 ~]# ./drp-raid
[
{
"ID": "0",
"Driver": "storcli7",
"PCI": {
"Bus": 10,
"Device": 0,
"Function": 0
},
"JBODCapable": false,
"RaidCapable": true,
"RaidLevels": [
"raid0",
"raid1",
"raid5",
"raid6",
"raid00",
"raid10",
"raid50",
"raid60"
],
"Volumes": [
{
"ControllerID": "0",
"ControllerDriver": "storcli7",
"ID": "0",
"Name": "",
"Status": "Optimal",
"RaidLevel": "raid1",
"Size": 499558383616,
"StripeSize": 65536,
"Spans": 1,
"SpanLength": 2,
"Disks": [
{
"ControllerID": "0",
"ControllerDriver": "storcli7",
"VolumeID": "0",
"Enclosure": "252",
"Size": 499558383616,
"UsedSize": 0,
"SectorCount": 975699968,
"PhysicalSectorSize": 512,
"LogicalSectorSize": 512,
"Slot": 0,
"Protocol": "sata",
"MediaType": "disk",
"Status": "Online, Spun Up",
"Info": {
"Coerced Size": "465.25 GB [0x3a280000 Sectors]",
"Commissioned Spare": "No",
"Connected Port Number": "2(path0)",
"Device Firmware Level": "1S04",
"Device Id": "1",
"Device Speed": "3.0Gb/s",
"Drive": "Not Certified",
"Drive has flagged a S.M.A.R.T alert": "No",
"Drive is formatted for PI information": "No",
"Drive's NCQ setting": "N/A",
"Drive's postion": "DiskGroup: 0, Span: 0, Arm: 0",
"Emergency Spare": "No",
"Enclosure Device ID": "252",
"Enclosure position": "0",
"FDE Capable": "Not Capable",
"FDE Enable": "Disable",
"Firmware state": "Online, Spun Up",
"Foreign State": "None",
"Inquiry Data": "WD-WMAYP8041031WDC WD5003ABYX-18WERA0 01.01S04",
"Last Predictive Failure Event Seq Number": "0",
"Link Speed": "3.0Gb/s",
"Locked": "Unlocked",
"Logical Sector Size": "512",
"Media Error Count": "0",
"Media Type": "Hard Disk Device",
"Needs EKM Attention": "No",
"Non Coerced Size": "465.261 GB [0x3a286030 Sectors]",
"Other Error Count": "0",
"PD": "1 Information",
"PD Type": "SATA",
"PI": "No PI",
"PI Eligibility": "No",
"Physical Sector Size": "512",
"Port status": "Active",
"Port's Linkspeed": "3.0Gb/s",
"Predictive Failure Count": "0",
"Raw Size": "465.761 GB [0x3a386030 Sectors]",
"SAS Address(0)": "0x4433221103000000",
"Secured": "Unsecured",
"Sequence Number": "28",
"Shield Counter": "0",
"Slot Number": "0",
"Successful diagnostics completion on": "N/A",
"WWN": "50014ee0ae7b61c5"
}
},
{
"ControllerID": "0",
"ControllerDriver": "storcli7",
"VolumeID": "0",
"Enclosure": "252",
"Size": 499558383616,
"UsedSize": 0,
"SectorCount": 975699968,
"PhysicalSectorSize": 512,
"LogicalSectorSize": 512,
"Slot": 1,
"Protocol": "sata",
"MediaType": "disk",
"Status": "Online, Spun Up",
"Info": {
"Coerced Size": "465.25 GB [0x3a280000 Sectors]",
"Commissioned Spare": "No",
"Connected Port Number": "1(path0)",
"Device Firmware Level": "1S04",
"Device Id": "2",
"Device Speed": "3.0Gb/s",
"Drive": "Not Certified",
"Drive has flagged a S.M.A.R.T alert": "No",
"Drive is formatted for PI information": "No",
"Drive's NCQ setting": "N/A",
"Drive's postion": "DiskGroup: 0, Span: 0, Arm: 1",
"Emergency Spare": "No",
"Enclosure Device ID": "252",
"Enclosure position": "0",
"FDE Capable": "Not Capable",
"FDE Enable": "Disable",
"Firmware state": "Online, Spun Up",
"Foreign State": "None",
"Inquiry Data": "WD-WMAYP7926193WDC WD5003ABYX-18WERA0 01.01S04",
"Last Predictive Failure Event Seq Number": "0",
"Link Speed": "3.0Gb/s",
"Locked": "Unlocked",
"Logical Sector Size": "512",
"Media Error Count": "0",
"Media Type": "Hard Disk Device",
"Needs EKM Attention": "No",
"Non Coerced Size": "465.261 GB [0x3a286030 Sectors]",
"Other Error Count": "0",
"PD Type": "SATA",
"PI": "No PI",
"PI Eligibility": "No",
"Physical Sector Size": "512",
"Port status": "Active",
"Port's Linkspeed": "3.0Gb/s",
"Predictive Failure Count": "0",
"Raw Size": "465.761 GB [0x3a386030 Sectors]",
"SAS Address(0)": "0x4433221102000000",
"Secured": "Unsecured",
"Sequence Number": "28",
"Shield Counter": "0",
"Slot Number": "1",
"Successful diagnostics completion on": "N/A",
"WWN": "50014ee05925c428"
}
}
],
"Info": {
"Bad Blocks Exist": "No",
"Creation Date": "14-02-2018",
"Creation Time": "09:22:25 PM",
"Current Access Policy": "Read/Write",
"Current Cache Policy": "WriteThrough, ReadAhead, Direct, No Write Cache if Bad BBU",
"Default Access Policy": "Read/Write",
"Default Cache Policy": "WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU",
"Disk Cache Policy": "Disk's Default",
"Encryption Type": "None",
"Is VD Cached": "No",
"Logical Sector Size": "512",
"Mirror Data": "465.25 GB",
"Name": "",
"Number Of Drives": "2",
"Number of Spans": "1",
"PD": "0 Information",
"Physical Sector Size": "512",
"RAID Level": "Primary-1, Secondary-0, RAID Level Qualifier-0",
"Size": "465.25 GB",
"Span Depth": "1",
"State": "Optimal",
"Strip Size": "64 KB",
"VD has Emulated PD": "No",
"Virtual Drive": "0 (Target Id: 0)"
}
},
{
"ControllerID": "0",
"ControllerDriver": "storcli7",
"ID": "1",
"Name": "",
"Status": "Optimal",
"RaidLevel": "raid1",
"Size": 499558383616,
"StripeSize": 65536,
"Spans": 1,
"SpanLength": 2,
"Disks": [
{
"ControllerID": "0",
"ControllerDriver": "storcli7",
"VolumeID": "1",
"Enclosure": "252",
"Size": 499558383616,
"UsedSize": 0,
"SectorCount": 975699968,
"PhysicalSectorSize": 512,
"LogicalSectorSize": 512,
"Slot": 2,
"Protocol": "sata",
"MediaType": "disk",
"Status": "Online, Spun Up",
"Info": {
"Coerced Size": "465.25 GB [0x3a280000 Sectors]",
"Commissioned Spare": "No",
"Connected Port Number": "3(path0)",
"Device Firmware Level": "1S04",
"Device Id": "3",
"Device Speed": "3.0Gb/s",
"Drive": "Not Certified",
"Drive has flagged a S.M.A.R.T alert": "No",
"Drive is formatted for PI information": "No",
"Drive's NCQ setting": "N/A",
"Drive's postion": "DiskGroup: 1, Span: 0, Arm: 0",
"Emergency Spare": "No",
"Enclosure Device ID": "252",
"Enclosure position": "0",
"FDE Capable": "Not Capable",
"FDE Enable": "Disable",
"Firmware state": "Online, Spun Up",
"Foreign State": "None",
"Inquiry Data": "WD-WMAYP8040536WDC WD5003ABYX-18WERA0 01.01S04",
"Last Predictive Failure Event Seq Number": "0",
"Link Speed": "3.0Gb/s",
"Locked": "Unlocked",
"Logical Sector Size": "512",
"Media Error Count": "0",
"Media Type": "Hard Disk Device",
"Needs EKM Attention": "No",
"Non Coerced Size": "465.261 GB [0x3a286030 Sectors]",
"Other Error Count": "0",
"PD": "1 Information",
"PD Type": "SATA",
"PI": "No PI",
"PI Eligibility": "No",
"Physical Sector Size": "512",
"Port status": "Active",
"Port's Linkspeed": "3.0Gb/s",
"Predictive Failure Count": "0",
"Raw Size": "465.761 GB [0x3a386030 Sectors]",
"SAS Address(0)": "0x4433221101000000",
"Secured": "Unsecured",
"Sequence Number": "22",
"Shield Counter": "0",
"Slot Number": "2",
"Successful diagnostics completion on": "N/A",
"WWN": "50014ee0ae7b6632"
}
},
{
"ControllerID": "0",
"ControllerDriver": "storcli7",
"VolumeID": "1",
"Enclosure": "252",
"Size": 499558383616,
"UsedSize": 0,
"SectorCount": 975699968,
"PhysicalSectorSize": 512,
"LogicalSectorSize": 512,
"Slot": 3,
"Protocol": "sata",
"MediaType": "disk",
"Status": "Online, Spun Up",
"Info": {
"Coerced Size": "465.25 GB [0x3a280000 Sectors]",
"Commissioned Spare": "No",
"Connected Port Number": "0(path0)",
"Device Firmware Level": "1S04",
"Device Id": "0",
"Device Speed": "3.0Gb/s",
"Drive": "Not Certified",
"Drive has flagged a S.M.A.R.T alert": "No",
"Drive is formatted for PI information": "No",
"Drive's NCQ setting": "N/A",
"Drive's postion": "DiskGroup: 1, Span: 0, Arm: 1",
"Emergency Spare": "No",
"Enclosure Device ID": "252",
"Enclosure position": "0",
"Exit Code": "0x00",
"FDE Capable": "Not Capable",
"FDE Enable": "Disable",
"Firmware state": "Online, Spun Up",
"Foreign State": "None",
"Inquiry Data": "WD-WMAYP8042658WDC WD5003ABYX-18WERA0 01.01S04",
"Last Predictive Failure Event Seq Number": "0",
"Link Speed": "3.0Gb/s",
"Locked": "Unlocked",
"Logical Sector Size": "512",
"Media Error Count": "0",
"Media Type": "Hard Disk Device",
"Needs EKM Attention": "No",
"Non Coerced Size": "465.261 GB [0x3a286030 Sectors]",
"Other Error Count": "0",
"PD Type": "SATA",
"PI": "No PI",
"PI Eligibility": "No",
"Physical Sector Size": "512",
"Port status": "Active",
"Port's Linkspeed": "3.0Gb/s",
"Predictive Failure Count": "0",
"Raw Size": "465.761 GB [0x3a386030 Sectors]",
"SAS Address(0)": "0x4433221100000000",
"Secured": "Unsecured",
"Sequence Number": "22",
"Shield Counter": "0",
"Slot Number": "3",
"Successful diagnostics completion on": "N/A",
"WWN": "50014ee003d097f2"
}
}
],
"Info": {
"Bad Blocks Exist": "No",
"Creation Date": "14-02-2018",
"Creation Time": "09:23:09 PM",
"Current Access Policy": "Read/Write",
"Current Cache Policy": "WriteThrough, ReadAhead, Direct, No Write Cache if Bad BBU",
"Default Access Policy": "Read/Write",
"Default Cache Policy": "WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU",
"Disk Cache Policy": "Disk's Default",
"Encryption Type": "None",
"Is VD Cached": "No",
"Logical Sector Size": "512",
"Mirror Data": "465.25 GB",
"Name": "",
"Number Of Drives": "2",
"Number of Spans": "1",
"PD": "0 Information",
"Physical Sector Size": "512",
"RAID Level": "Primary-1, Secondary-0, RAID Level Qualifier-0",
"Size": "465.25 GB",
"Span Depth": "1",
"State": "Optimal",
"Strip Size": "64 KB",
"VD has Emulated PD": "No",
"Virtual Drive": "1 (Target Id: 1)"
}
}
],
"Disks": [
{
"ControllerID": "0",
"ControllerDriver": "storcli7",
"VolumeID": "",
"Enclosure": "252",
"Size": 499558383616,
"UsedSize": 0,
"SectorCount": 975699968,
"PhysicalSectorSize": 512,
"LogicalSectorSize": 512,
"Slot": 0,
"Protocol": "sata",
"MediaType": "disk",
"Status": "Online, Spun Up",
"Info": {
"Coerced Size": "465.25 GB [0x3a280000 Sectors]",
"Commissioned Spare": "No",
"Connected Port Number": "2(path0)",
"Device Firmware Level": "1S04",
"Device Id": "1",
"Device Speed": "3.0Gb/s",
"Drive": "Not Certified",
"Drive has flagged a S.M.A.R.T alert": "No",
"Drive is formatted for PI information": "No",
"Drive's NCQ setting": "N/A",
"Drive's postion": "DiskGroup: 0, Span: 0, Arm: 0",
"Emergency Spare": "No",
"Enclosure Device ID": "252",
"Enclosure position": "0",
"FDE Capable": "Not Capable",
"FDE Enable": "Disable",
"Firmware state": "Online, Spun Up",
"Foreign State": "None",
"Inquiry Data": "WD-WMAYP8041031WDC WD5003ABYX-18WERA0 01.01S04",
"Last Predictive Failure Event Seq Number": "0",
"Link Speed": "3.0Gb/s",
"Locked": "Unlocked",
"Logical Sector Size": "512",
"Media Error Count": "0",
"Media Type": "Hard Disk Device",
"Needs EKM Attention": "No",
"Non Coerced Size": "465.261 GB [0x3a286030 Sectors]",
"Other Error Count": "0",
"PD Type": "SATA",
"PI": "No PI",
"PI Eligibility": "No",
"Physical Sector Size": "512",
"Port status": "Active",
"Port's Linkspeed": "3.0Gb/s",
"Predictive Failure Count": "0",
"Raw Size": "465.761 GB [0x3a386030 Sectors]",
"SAS Address(0)": "0x4433221103000000",
"Secured": "Unsecured",
"Sequence Number": "28",
"Shield Counter": "0",
"Slot Number": "0",
"Successful diagnostics completion on": "N/A",
"WWN": "50014ee0ae7b61c5"
}
},
{
"ControllerID": "0",
"ControllerDriver": "storcli7",
"VolumeID": "",
"Enclosure": "252",
"Size": 499558383616,
"UsedSize": 0,
"SectorCount": 975699968,
"PhysicalSectorSize": 512,
"LogicalSectorSize": 512,
"Slot": 1,
"Protocol": "sata",
"MediaType": "disk",
"Status": "Online, Spun Up",
"Info": {
"Coerced Size": "465.25 GB [0x3a280000 Sectors]",
"Commissioned Spare": "No",
"Connected Port Number": "1(path0)",
"Device Firmware Level": "1S04",
"Device Id": "2",
"Device Speed": "3.0Gb/s",
"Drive": "Not Certified",
"Drive has flagged a S.M.A.R.T alert": "No",
"Drive is formatted for PI information": "No",
"Drive's NCQ setting": "N/A",
"Drive's postion": "DiskGroup: 0, Span: 0, Arm: 1",
"Emergency Spare": "No",
"Enclosure Device ID": "252",
"Enclosure position": "0",
"FDE Capable": "Not Capable",
"FDE Enable": "Disable",
"Firmware state": "Online, Spun Up",
"Foreign State": "None",
"Inquiry Data": "WD-WMAYP7926193WDC WD5003ABYX-18WERA0 01.01S04",
"Last Predictive Failure Event Seq Number": "0",
"Link Speed": "3.0Gb/s",
"Locked": "Unlocked",
"Logical Sector Size": "512",
"Media Error Count": "0",
"Media Type": "Hard Disk Device",
"Needs EKM Attention": "No",
"Non Coerced Size": "465.261 GB [0x3a286030 Sectors]",
"Other Error Count": "0",
"PD Type": "SATA",
"PI": "No PI",
"PI Eligibility": "No",
"Physical Sector Size": "512",
"Port status": "Active",
"Port's Linkspeed": "3.0Gb/s",
"Predictive Failure Count": "0",
"Raw Size": "465.761 GB [0x3a386030 Sectors]",
"SAS Address(0)": "0x4433221102000000",
"Secured": "Unsecured",
"Sequence Number": "28",
"Shield Counter": "0",
"Slot Number": "1",
"Successful diagnostics completion on": "N/A",
"WWN": "50014ee05925c428"
}
},
{
"ControllerID": "0",
"ControllerDriver": "storcli7",
"VolumeID": "",
"Enclosure": "252",
"Size": 499558383616,
"UsedSize": 0,
"SectorCount": 975699968,
"PhysicalSectorSize": 512,
"LogicalSectorSize": 512,
"Slot": 2,
"Protocol": "sata",
"MediaType": "disk",
"Status": "Online, Spun Up",
"Info": {
"Coerced Size": "465.25 GB [0x3a280000 Sectors]",
"Commissioned Spare": "No",
"Connected Port Number": "3(path0)",
"Device Firmware Level": "1S04",
"Device Id": "3",
"Device Speed": "3.0Gb/s",
"Drive": "Not Certified",
"Drive has flagged a S.M.A.R.T alert": "No",
"Drive is formatted for PI information": "No",
"Drive's NCQ setting": "N/A",
"Drive's postion": "DiskGroup: 1, Span: 0, Arm: 0",
"Emergency Spare": "No",
"Enclosure Device ID": "252",
"Enclosure position": "0",
"FDE Capable": "Not Capable",
"FDE Enable": "Disable",
"Firmware state": "Online, Spun Up",
"Foreign State": "None",
"Inquiry Data": "WD-WMAYP8040536WDC WD5003ABYX-18WERA0 01.01S04",
"Last Predictive Failure Event Seq Number": "0",
"Link Speed": "3.0Gb/s",
"Locked": "Unlocked",
"Logical Sector Size": "512",
"Media Error Count": "0",
"Media Type": "Hard Disk Device",
"Needs EKM Attention": "No",
"Non Coerced Size": "465.261 GB [0x3a286030 Sectors]",
"Other Error Count": "0",
"PD Type": "SATA",
"PI": "No PI",
"PI Eligibility": "No",
"Physical Sector Size": "512",
"Port status": "Active",
"Port's Linkspeed": "3.0Gb/s",
"Predictive Failure Count": "0",
"Raw Size": "465.761 GB [0x3a386030 Sectors]",
"SAS Address(0)": "0x4433221101000000",
"Secured": "Unsecured",
"Sequence Number": "22",
"Shield Counter": "0",
"Slot Number": "2",
"Successful diagnostics completion on": "N/A",
"WWN": "50014ee0ae7b6632"
}
},
{
"ControllerID": "0",
"ControllerDriver": "storcli7",
"VolumeID": "",
"Enclosure": "252",
"Size": 499558383616,
"UsedSize": 0,
"SectorCount": 975699968,
"PhysicalSectorSize": 512,
"LogicalSectorSize": 512,
"Slot": 3,
"Protocol": "sata",
"MediaType": "disk",
"Status": "Online, Spun Up",
"Info": {
"Coerced Size": "465.25 GB [0x3a280000 Sectors]",
"Commissioned Spare": "No",
"Connected Port Number": "0(path0)",
"Device Firmware Level": "1S04",
"Device Id": "0",
"Device Speed": "3.0Gb/s",
"Drive": "Not Certified",
"Drive has flagged a S.M.A.R.T alert": "No",
"Drive is formatted for PI information": "No",
"Drive's NCQ setting": "N/A",
"Drive's postion": "DiskGroup: 1, Span: 0, Arm: 1",
"Emergency Spare": "No",
"Enclosure Device ID": "252",
"Enclosure position": "0",
"Exit Code": "0x00",
"FDE Capable": "Not Capable",
"FDE Enable": "Disable",
"Firmware state": "Online, Spun Up",
"Foreign State": "None",
"Inquiry Data": "WD-WMAYP8042658WDC WD5003ABYX-18WERA0 01.01S04",
"Last Predictive Failure Event Seq Number": "0",
"Link Speed": "3.0Gb/s",
"Locked": "Unlocked",
"Logical Sector Size": "512",
"Media Error Count": "0",
"Media Type": "Hard Disk Device",
"Needs EKM Attention": "No",
"Non Coerced Size": "465.261 GB [0x3a286030 Sectors]",
"Other Error Count": "0",
"PD Type": "SATA",
"PI": "No PI",
"PI Eligibility": "No",
"Physical Sector Size": "512",
"Port status": "Active",
"Port's Linkspeed": "3.0Gb/s",
"Predictive Failure Count": "0",
"Raw Size": "465.761 GB [0x3a386030 Sectors]",
"SAS Address(0)": "0x4433221100000000",
"Secured": "Unsecured",
"Sequence Number": "22",
"Shield Counter": "0",
"Slot Number": "3",
"Successful diagnostics completion on": "N/A",
"WWN": "50014ee003d097f2"
}
}
],
"Info": {
"Access Policy": "Yes",
"Alarm": "Present",
"Alarm Control": "Yes",
"Alarm Disable": "Yes",
"Allow Boot with Preserved Cache": "No",
"Allow Ctrl Encryption": "No",
"Allow HDD SAS/SATA Mix in VD": "Yes",
"Allow HDD/SSD Mix in VD": "Yes",
"Allow Mix in Enclosure": "Yes",
"Allow Mixed Redundancy on Array": "No",
"Allow SATA in Cluster": "No",
"Allow SSD SAS/SATA Mix in VD": "Yes",
"Allowed Device Type": "SAS/SATA Mix",
"Any Offline VD Cache Preserved": "No",
"Auto Detect BackPlane Enable": "SGPIO/i2c SEP",
"Auto Detect BackPlane Enabled": "SGPIO/i2c SEP",
"Auto Enhanced Import": "Yes",
"Auto Rebuild": "Enabled",
"BBU": "Absent",
"BGI Rate": "30%",
"BIOS Continue on Error": "Yes",
"BIOS Enumerate VDs": "Yes",
"BIOS Version": "3.30.02.2_4.16.08.00_0x06060A05",
"BOOT Version": "09.250.01.219",
"Background Rate": "30",
"Battery FRU": "N/A",
"Battery Warning": "Disabled",
"Block SSD Write Disk Cache Change": "No",
"Boot Block Version": "2.02.00.00-0000",
"Boot Volume Supported": "NO",
"BreakMirror RAID Support": "Yes",
"CC Rate": "Yes",
"Cache Flush Interval": "4s",
"Cache When BBU Bad": "Disabled",
"Cached IO": "No",
"Check Consistency Rate": "30%",
"ChipRevision": "B4",
"Cluster Active": "No",
"Cluster Disable": "Yes",
"Cluster Mode": "Disabled",
"Cluster Permitted": "No",
"Cluster Support": "No",
"Coercion Mode": "None",
"Controller Id": "0000",
"Critical Disks": "0",
"Current Size of CacheCade": "0 GB",
"Current Size of FW Cache": "346 MB",
"Current Time": "21:24:30 2/14, 2018",
"Dedicated Hot Spare": "Yes",
"Default LD PowerSave Policy": "Controller Defined",
"Default spin down time in minutes": "30",
"Degraded": "0",
"Delay Among Spinup Groups": "2s",
"Delay during POST": "0",
"Deny CC": "No",
"Deny Clear": "No",
"Deny Force Failed": "No",
"Deny Force Good/Bad": "No",
"Deny Locate": "No",
"Deny Missing Replace": "No",
"Deny SCSI Passthrough": "No",
"Deny SMP Passthrough": "No",
"Deny STP Passthrough": "No",
"Device Id": "0079",
"Device Interface": "PCIE",
"Direct PD Mapping": "No",
"Dirty LED Shows Drive Activity": "No",
"Disable Copyback": "No",
"Disable Ctrl-R": "Yes",
"Disable Join Mirror": "No",
"Disable Online Controller Reset": "No",
"Disable Online PFK Change": "No",
"Disable Puncturing": "No",
"Disable Spin Down of hot spares": "No",
"Disk Cache Policy": "Yes",
"Disks": "4",
"ECC Bucket Count": "0",
"Ecc Bucket Leak Rate": "1440 Minutes",
"Ecc Bucket Size": "15",
"Enable Copyback on SMART": "No",
"Enable Copyback to SSD on SMART Error": "Yes",
"Enable JBOD": "No",
"Enable LDBBM": "Yes",
"Enable Led Header": "Yes",
"Enable SSD Patrol Read": "No",
"Enable Shield State": "No",
"Enable Spin Down of UnConfigured Drives": "Yes",
"Enable Web BIOS": "Yes",
"EnableCrashDump": "No",
"EnableLDBBM": "Yes",
"Exit Code": "0x00",
"Expose Enclosure Devices": "Enabled",
"FW Package Build": "12.15.0-0239",
"FW Version": "2.130.403-4660",
"Failed Disks": "0",
"Flash": "Present",
"Flush Time": "4 seconds",
"Force Offline": "Yes",
"Force Online": "Yes",
"Force Rebuild": "Yes",
"Foreign Config Import": "Yes",
"Global Hot Spares": "Yes",
"Host Interface": "PCIE",
"Host Request Reordering": "Enabled",
"IO Policy": "Yes",
"Interrupt Throttle Active Count": "16",
"Interrupt Throttle Completion": "50us",
"LED Show Drive Activity": "Yes",
"Load Balance Mode": "Auto",
"Maintain PD Fail History": "Enabled",
"Max Arms Per VD": "32",
"Max Arrays": "128",
"Max Chained Enclosures": "16",
"Max Configurable CacheCade Size": "0 GB",
"Max Data Transfer Size": "8192 sectors",
"Max Drives to Spinup at One Time": "4",
"Max LD per array": "16",
"Max Number of VDs": "64",
"Max Parallel Commands": "1008",
"Max SGE Count": "80",
"Max Spans Per VD": "8",
"Max Strip Size": "1.0 MB",
"Max Strips PerIO": "42",
"Maximum number of direct attached drives to spin up in 1 min": "120",
"Memory": "Present",
"Memory Correctable Errors": "0",
"Memory Size": "512MB",
"Memory Uncorrectable Errors": "0",
"Mfg. Date": "03/13/12",
"Min Strip Size": "8 KB",
"NCQ": "No",
"NVDATA Version": "2.09.03-0058",
"NVRAM": "Present",
"Number of Backend Port": "8",
"Number of Frontend Port": "0",
"Offline": "0",
"On board Expander": "Absent",
"PFK TrailTime Remaining": "0 days 0 hours",
"PFK in NVRAM": "No",
"POST delay": "90 seconds",
"PR Correct Unconfigured Areas": "Yes",
"PR Rate": "30%",
"Patrol Read Rate": "Yes",
"Phy Polarity": "0",
"Phy PolaritySplit": "0",
"Physical Devices": "5",
"Physical Drive Coercion Mode": "Disabled",
"Point In Time Progress": "No",
"Power Saving option": "Don't Auto spin down Configured Drives",
"Power Savings": "No",
"PreBoot CLI Enabled": "Yes",
"Preboot CLI Version": "04.04-020:#%00009",
"Predictive Fail Poll Interval": "300sec",
"Product Name": "LSI MegaRAID SAS 9260-8i",
"RAID Level Supported": "RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span",
"Read Policy": "Yes",
"Rebuild Rate": "30%",
"Reconstruct Rate": "Yes",
"Reconstruction": "Yes",
"Reconstruction Rate": "30%",
"Restore Hot Spare on Insertion": "No",
"Restore HotSpare on Insertion": "Disabled",
"Revertible Hot Spares": "Yes",
"Revision No": "79B",
"Rework Date": "00/00/00",
"SAS Address": "500605b004872390",
"SAS Disable": "No",
"SMART Mode": "Mode 6",
"Security Key Assigned": "No",
"Security Key Failed": "No",
"Security Key Not Backedup": "No",
"Self Diagnostic": "Yes",
"Serial Debugger": "Present",
"Serial No": "SV21106771",
"Snapshot Enabled": "No",
"Spanning": "Yes",
"Spin Down Mode": "None",
"Spin Down time": "30",
"Strip Size": "256kB",
"SubDeviceId": "9261",
"SubVendorId": "1000",
"Support Boot Time PFK Change": "No",
"Support Breakmirror": "No",
"Support PFK": "Yes",
"Support PI": "No",
"Support Security": "No",
"Support Shield State": "No",
"Support Temperature": "Yes",
"Support the OCE without adding drives": "Yes",
"Supported Drives": "SAS, SATA",
"T10 Power State": "No",
"TPM": "Absent",
"TTY Log In Flash": "No",
"Temperature sensor for ROC": "Absent",
"Temperature sensor for controller": "Absent",
"Time taken to detect CME": "60s",
"Topology Type": "None",
"Treat Single span R1E as R10": "No",
"Un-Certified Hard Disk Drives": "Allow",
"Upgrade Key": "Absent",
"Use FDE Only": "No",
"Use disk activity for locate": "No",
"Vendor Id": "1000",
"Virtual Drives": "2",
"WebBIOS Version": "6.0-54-e_50-Rel",
"Write Policy": "Yes",
"ZCR Config": "Unknown",
"Zero Based Enclosure Enumeration": "No"
}
}
]
[root@df8-bc-12-41-c4-72 ~]# ./drp-raid -clear